Found 9985 publications. Showing page 73 of 400:
Grenseområdene Norge-Russland. Luft- og nedbørkvalitet 2020.
Smelteverkene i nordvest-Russland slapp ut store mengder svoveldioksid (SO2) og tungmetaller. Utslippene påvirket luft- og nedbørkvalitet i grenseområdene. Miljøovervåkingen viser at grenseverdier for SO2 er overholdt i kalenderåret 2020, samt for vinter 2019/20. Smelteverket i Nikel stengte ned 23. desember 2020 og dette er ventet å gi stor nedgang i
forurensningen i grenseområdene. Målsettingsverdier for Ni, As og Cd er overholdt.
NILU
2021
2021
This study introduces an Earth observation (EO)-based system which is capable of operationally estimating and continuously monitoring the ultraviolet index (UVI) in Europe. UVIOS (i.e., UV-Index Operating System) exploits a synergy of radiative transfer models with high-performance computing and EO data from satellites (Meteosat Second Generation and Meteorological Operational Satellite-B) and retrieval processes (Tropospheric Emission Monitoring Internet Service, Copernicus Atmosphere Monitoring Service and the Global Land Service). It provides a near-real-time nowcasting and short-term forecasting service for UV radiation over Europe. The main atmospheric inputs for the UVI simulations include ozone, clouds and aerosols, while the impacts of ground elevation and surface albedo are also taken into account. The UVIOS output is the UVI at high spatial and temporal resolution (5 km and 15 min, respectively) for Europe (i.e., 1.5 million pixels) in real time. The UVI is empirically related to biologically important UV dose rates, and the reliability of this EO-based solution was verified against ground-based measurements from 17 stations across Europe. Stations are equipped with spectral, broadband or multi-filter instruments and cover a range of topographic and atmospheric conditions. A period of over 1 year of forecasted 15 min retrievals under all-sky conditions was compared with the ground-based measurements. UVIOS forecasts were within ±0.5 of the measured UVI for at least 70 % of the data compared at all stations. For clear-sky conditions the agreement was better than 0.5 UVI for 80 % of the data. A sensitivity analysis of EO inputs and UVIOS outputs was performed in order to quantify the level of uncertainty in the derived products and to identify the covariance between the accuracy of the output and the spatial and temporal resolution and the quality of the inputs. Overall, UVIOS slightly overestimated the UVI due to observational uncertainties in inputs of cloud and aerosol. This service will hopefully contribute to EO capabilities and will assist the provision of operational early warning systems that will help raise awareness among European Union citizens of the health implications of high UVI doses.
2021
Evaluation and optimization of ICOS atmosphere station data as part of the labeling process
The Integrated Carbon Observation System (ICOS) is a pan-European research infrastructure which provides harmonized and high-precision scientific data on the carbon cycle and the greenhouse gas budget. All stations have to undergo a rigorous assessment before being labeled, i.e., receiving approval to join the network. In this paper, we present the labeling process for the ICOS atmosphere network through the 23 stations that were labeled between November 2017 and November 2019. We describe the labeling steps, as well as the quality controls, used to verify that the ICOS data (CO2, CH4, CO and meteorological measurements) attain the expected quality level defined within ICOS. To ensure the quality of the greenhouse gas data, three to four calibration gases and two target gases are measured: one target two to three times a day, the other gases twice a month. The data are verified on a weekly basis, and tests on the station sampling lines are performed twice a year. From these high-quality data, we conclude that regular calibrations of the CO2, CH4 and CO analyzers used here (twice a month) are important in particular for carbon monoxide (CO) due to the analyzer's variability and that reducing the number of calibration injections (from four to three) in a calibration sequence is possible, saving gas and extending the calibration gas lifespan. We also show that currently, the on-site water vapor correction test does not deliver quantitative results possibly due to environmental factors. Thus the use of a drying system is strongly recommended. Finally, the mandatory regular intake line tests are shown to be useful in detecting artifacts and leaks, as shown here via three different examples at the stations.
2021
Skogens helsetilstand i Norge. Resultater fra skogskadeovervåkingen i 2020.
Skogens helsetilstand påvirkes i stor grad av klima og værforhold, enten direkte ved tørke, frost og vind, eller indirekte ved at klimaet påvirker omfanget av soppsykdommer og insektangrep. Klimaendringene og den forventede økningen i klimarelaterte skogskader gir store utfordringer for forvaltningen av framtidas skogressurser. Det samme gjør invaderende skadegjørere, både allerede etablerte arter og nye som kan komme til Norge i nær framtid. I denne rapporten presenteres resultater fra skogskadeovervåkingen i Norge i 2020 og trender over tid.
I den landsrepresentative skogovervåkingen har kronetettheten hos gran og furu holdt seg stabil i 2020 sammenlignet med tidligere år. Det ble registrert lite misfarging hos bartrærne.
Skadenivået hos både bartrær, bjørk og andre løvtrær var lavere enn i 2019. Abiotiske faktorer med snø, vind og tørke som de viktigste årsakene dominerte skadebildet hos alle treslag.
Kjemiske analyser av luft og nedbør i den intensive skogovervåkingen viser at det fortsatt er høyest verdier av antropogene svovel- og nitrogenforbindelser på den sørligste overvåkingsflata i Birkenes grunnet langtransportert forurensing. Den høyeste konsentrasjonen av nitrogendioksid i luft ble målt på stasjonen i Hurdal i 2020, noe som skyldes utslipp fra veitrafikken i regionen. Det var lave nivåer av bakkenært ozon i Norge i 2020 og ingen overskridelser av UNECEs grenseverdi på 5000 ppb-timer for skog. Vegetasjonsanalysene fra Hurdal har påvist en endring i bunn-vegetasjonens artssammensetning grunnet økt lystilgang og mye barnålstrø. Både hogst utenfor overvåkingsflata og flere skrantende, råteangrepne og døde grantrær i flata har bidratt til økt lystilgang og til større strømengde på bakken. Mange grantrær på flata i Hurdal er sterkt preget av råte med lav kronetetthet og mye misfarging. Flere trær på flata har dødd de seinere årene som følge av råteskader, ofte i kombinasjon med andre faktorer som vindfelling og skader etter tørken i 2018 med påfølgende barkbilleangrep.
Overvåking av bjørkemålere har vist at fjellbjørkeskogen både i Nord-Norge og fjellregionene i sørlige halvdel av landet har vært utsatt for betydelige utbrudd av bjørkemålere i løpet av perioden 2012–2018. Overvåkingsdata fra 2019 og 2020 tyder imidlertid på at målerbestandene nå er lave eller i sterk tilbakegang i det meste av landet. I Troms har målerbestandene allerede nådd et bunnpunkt, og bestandene er nedadgående også i fjellet i Sør-Norge. Vi forventer derfor at skogen i mesteparten av Norge vil bli mindre utsatt for angrep av bjørkemålere de neste par årene.
De fleste fylkene hadde en økning i fangstverdiene i barkbilleovervåkingen i 2020-sesongen. Alle fangstverdiene var imidlertid under 10 000 biller per felle, mens de høyeste verdiene ved slutten av utbruddet på 1970-tallet var rundt 25 000 biller per felle. Fylkene rundt Oslofjorden hadde noen lokale tilfeller av tørke- og barkbilleskader. Det ble ikke funnet noen tydelig økning av fellefangstene i tiden for en annen generasjon, men modellberegninger viser at stor granbarkbille har nok døgngrader til å gjennomføre to generasjoner før overvintring.
I august 2020 ble soppen Diplodia sapinea funnet på sterkt skadet vrifuru i Ås kommune. Tidligere har det blitt gjort noen få funn av soppen på andre bartrearter i det samme området. D. sapinea er vanlig i varmere strøk på flere kontinenter, spesielt på furuarter. De pågående klima-endringene har trolig bidratt til at soppen har kunnet spre og etablere seg mot nord, men vi kan heller ikke utelukke innførsel av soppen via plantemateriale til bruk i grøntanlegg eller skog. D. sapinea er trolig bare i etableringsfasen i Norge, og har til dags dato gjort liten skade på våre stedegne bartrær.....
NIBIO
2021
2021
2021
The long-term time trends of atmospheric pollutants at eight Arctic monitoring stations are reported. The work was conducted under the Arctic Monitoring and Assessment Programme (AMAP) of the Arctic Council. The monitoring stations were: Alert, Canada; Zeppelin, Svalbard; Stórhöfði, Iceland; Pallas, Finland; Andøya, Norway; Villum Research Station, Greenland; Tiksi and Amderma, Russia. Persistent organic pollutants (POPs) such as α- and γ-hexachlorocyclohexane (HCH), polychlorinated biphenyls (PCBs), α-endosulfan, chlordane, dichlorodiphenyltrichloroethane (DDT) and polybrominated diphenyl ethers (PBDEs) showed declining trends in air at all stations. However, hexachlorobenzene (HCB), one of the initial twelve POPs listed in the Stockholm Convention in 2004, showed either increasing or non-changing trends at the stations. Many POPs demonstrated seasonality but the patterns were not consistent among the chemicals and stations. Some chemicals showed winter minimum and summer maximum concentrations at one station but not another, and vice versa. The ratios of chlordane isomers and DDT species showed that they were aged residues. Time trends of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) were showing decreasing concentrations at Alert, Zeppelin and Andøya. The Chemicals of Emerging Arctic Concern (CEAC) were either showing stable or increasing trends. These include methoxychlor, perfluorohexane sulfonic acid (PFHxS), 6:2 fluorotelomer alcohol, and C9-C11 perfluorocarboxylic acids (PFCAs). We have demonstrated the importance of monitoring CEAC before they are being regulated because model calculations to predict their transport mechanisms and fate cannot be made due to the lack of emission inventories. We should maintain long-term monitoring programmes with consistent data quality in order to evaluate the effectiveness of chemical control efforts taken by countries worldwide.
2021
Biomonitoring studies are helpful tools and can increase our knowledge on time trends in human blood concentrations of PFASs: how they relate to emission trends and the potential prenatal exposure for future generations. In this study, serum was sampled in cross-sections of men and women who were 30 years old in each of the years 1986, 1994, 2001, and 2007 in Northern Norway and analyzed for 23 PFASs. Differences in serum concentrations across sampling years were investigated graphically and with significance testing and compared with those observed in our previous longitudinal study using repeated individual measurements in older men in the same years. The results demonstrate overall increasing blood burdens of PFASs in men and women in reproductively active ages during 1986–2001 and decreases until 2007. However, longer chained PFASs were still increasing in 2007 indicating divergent time trends between the different PFASs, underlining the importance of continued biomonitoring. Comparisons between 30-year-old men and older men within the same population demonstrated variation in time trends in the exact same years, underlining that biomonitoring studies must regard historic exposures and birth cohort effects.
2021
While occupational inhalation exposure to gaseous elemental mercury (GEM) has decreased in many workplaces as mercury is being removed from most products and processes, it continues to be a concern for those engaged in artisanal and small-scale gold mining or in recycling mercury-containing products. Recently, stationary and personal passive air samplers based on activated carbon sorbents and radial diffusive barriers have been shown to be suitable for measuring GEM concentrations across the range relevant for chronic health effects. Here, we used a combination of stationary and personal passive samplers to characterize the inhalation exposure to GEM of individuals living and working in two Ghanaian gold mining communities and working at a Norwegian e-waste recycling facility. Exposure concentrations ranging from <7 ng m−3 to >500 μg m−3 were observed, with the higher end of the range occurring in one gold mining community. Large differences in the GEM exposure averaged over the length of a workday between individuals can be rationalized by their activity and proximity to mercury sources. In each of the three settings, the measured exposure of the highest exposed individuals exceeded the highest concentration recorded with a stationary sampler, presumably because those individuals were engaged in an activity that generated or involved GEM vapors. High day-to-day variability in exposure for those who participated on more than one day, suggests the need for sampling over multiple days for reliable exposure characterization. Overall, a combination of personal and stationary passive sampling is a cost-effective approach that cannot only provide information on exposure levels relative to regulatory thresholds, but also can identify emission hotspots and therefore guide mitigation measures.
2021
2021
2021
Understanding aerosol–cloud–climate interactions in the Arctic is key to predicting the climate in this rapidly changing region. Whilst many studies have focused on submicrometer aerosol (diameter less than 1 µm), relatively little is known about the supermicrometer aerosol (diameter above 1 µm). Here, we present a cluster analysis of multiyear (2015–2019) aerodynamic volume size distributions, with diameter ranging from 0.5 to 20 µm, measured continuously at the Gruvebadet Observatory in the Svalbard archipelago. Together with aerosol chemical composition data from several online and offline measurements, we apportioned the occurrence of the coarse-mode aerosols during the study period (mainly from March to October) to anthropogenic (two sources, 27 %) and natural (three sources, 73 %) origins. Specifically, two clusters are related to Arctic haze with high levels of black carbon, sulfate and accumulation mode (0.1–1 µm) aerosol. The first cluster (9 %) is attributed to ammonium sulfate-rich Arctic haze particles, whereas the second one (18 %) is attributed to larger-mode aerosol mixed with sea salt. The three natural aerosol clusters were open-ocean sea spray aerosol (34 %), mineral dust (7 %) and an unidentified source of sea spray-related aerosol (32 %). The results suggest that sea-spray-related aerosol in polar regions may be more complex than previously thought due to short- and long-distance origins and mixtures with Arctic haze, biogenic and likely blowing snow aerosols. Studying supermicrometer natural aerosol in the Arctic is imperative for understanding the impacts of changing natural processes on Arctic aerosol.
2021
Polyurethane foam passive air samplers (PUF-PAS) are the most common type of passive air sampler used for a range of semi-volatile organic compounds (SVOCs), including regulated persistent organic pollutants (POPs) and polycyclic aromatic hydrocarbons (PAHs), and emerging contaminants (e.g., novel flame retardants, phthalates, current-use pesticides). Data from PUF-PAS are key indicators of effectiveness of global regulatory actions on SVOCs, such as the Global Monitoring Plan of the Stockholm Convention on Persistent Organic Pollutants. While most PUF-PAS use similar double-dome metal shielding, there is no standardized dome size, shape, or deployment configuration, with many different PUF-PAS designs used in regional and global monitoring. Yet, no information is available on the comparability of data from studies using different PUF-PAS designs. We brought together 12 types of PUF-PAS used by different research groups around the world and deployed them in a multi-part intercomparison to evaluate the variability in reported concentrations introduced by different elements of PAS monitoring. PUF-PAS were deployed for 3 months in outdoor air in Kjeller, Norway in 2015–2016 in three phases to capture (1) the influence of sampler design on data comparability, (2) the influence of analytical variability when samplers are analyzed at different laboratories, and (3) the overall variability in global monitoring data introduced by differences in sampler configurations and analytical methods. Results indicate that while differences in sampler design (in particular, the spacing between the upper and lower sampler bowls) account for up to 50 % differences in masses collected by samplers, the variability introduced by analysis in different laboratories far exceeds this amount, resulting in differences spanning orders of magnitude for POPs and PAHs. The high level of variability due to analysis in different laboratories indicates that current SVOC air sampling data (i.e., not just for PUF-PAS but likely also for active air sampling) are not directly comparable between laboratories/monitoring programs. To support on-going efforts to mobilize more SVOC data to contribute to effectiveness evaluation, intercalibration exercises to account for uncertainties in air sampling, repeated at regular intervals, must be established to ensure analytical comparability and avoid biases in global-scale assessments of SVOCs in air caused by differences in laboratory performance.
2021
This paper presents the validation results of Aerosol Optical Depth (AOD) retrieved from the Spinning Enhanced Visible Infrared Radiometer (SEVIRI) data using the near-real-time algorithm further developed in the frame of the Satellite-based Monitoring Initiative for Regional Air quality (SAMIRA) project. The SEVIRI AOD was compared against multiple data sources: six stations of the Aerosol Robotic Network (AERONET) in Romania and Poland, three stations of the Aerosol Research Network in Poland (Poland–AOD) and Moderate Resolution Imaging Spectroradiometer (MODIS) data overlapping Romania, Czech Republic and Poland. The correlation values between a four-month dataset (June–September 2014) from SEVIRI and the closest temporally available data for both ground-based and satellite products were identified. The comparison of the SEVIRI AOD with the AERONET AOD observations generally shows a good correlation (r = 0.48–0.83). The mean bias is 0.10–0.14 and the root mean square error RMSE is between 0.11 and 0.15 for all six stations cases. For the comparison with Poland–AOD correlation values are 0.55 to 0.71. The mean bias is 0.04–0.13 and RMSE is between 0.10 and 0.14. As for the intercomparison to MODIS AOD, correlations values were generally lower (r = 0.33–0.39). Biases of −0.06 to 0.24 and RMSE of 0.04 to 0.28 were in good agreement with the ground–stations retrievals. The validation of SEVIRI AOD with AERONET results in the best correlations followed by the Poland–AOD network and MODIS retrievals. The average uncertainty estimates are evaluated resulting in most of the AOD values falling above the expected error range. A revised uncertainty estimate is proposed by including the observed bias form the AERONET validation efforts.
2021
2021
DNA damage and repair activity are often assessed in blood samples from humans in different types of molecular epidemiology studies. However, it is not always feasible to analyse the s#38les on the day of collection without any type of storage. For instance, certain studies use repeated sampling of cells from the same subject or samples from different subjects collected at different time-points, and it is desirable to analyse all these samples in the same comet assay experiment. In addition, flawless comet assay analyses on frozen samples opens up for the possibility of using this technique on biobank material. In this article we discuss the use of cryopreserved peripheral blood mononuclear cells (PBMCs), buffy coat (BC) and whole blood (WB) for analysis of DNA damage and repair using the comet assay. The published literature and the authors’ experiences indicate that various types of blood samples can be cryopreserved with only minor effect on the basal level of DNA damage. There is evidence to suggest that WB and PBMCs can be cryopreserved for several years without much effect on the level of DNA damage. However, care should be taken when cryopreserving WB and BCs. It is possible to use either fresh or frozen samples of blood cells, but results from fresh and frozen cells should not be used in the same dataset. The article outlines detailed protocols for the cryopreservation of PBMCs, BCs and WB samples.
2021
2021